Free newsletter:
NDT promos & resources.
 


 

 
 
There are 0 items currently in your shopping cart
1 - 3 of 22
Next
Concrete >> Maturity & Temperature
James Instruments, Inc. : Chloride Test
Determines Chloride Ion Content in wet and dry materials
 

Measures the amount of chloride present in wet or dry concrete.

The Chlorimeter produces results on-site, within minutes that are accurate and comparable to expensive laboratory tests. It measures the electrochemical reaction of a weighted sample placed in an extraction liquid. It automatically shows a temperature compensated reading of percent of chlorides on its digital display. A wide range - from 0.002 to 2% chloride by weight is covered.

Please Note: Check an item and click on the text "Add To Cart" in order to select an item.  Simply checking a box will NOT add the item to your shopping cart.
Model Description Part No. Price Add To Cart

C-CL-3000

 James Instruments, Inc. Chlorimeter Chloride Field Test System

28-C-CL-3000

Please email us or
call 1-800-635-9108 or 913-432-7080
for current pricing.

Concrete >> Maturity & Temperature
James Instruments, Inc. : Gecor 8
Advanced rebar corrosion rate determination test
 

James Instruments, Inc. Gecor 8

World's most advanced system for analyzing corrosion of concrete reinforcing steel in existing structures

James Instruments Gecor 8 represents the latest technology in steel reinforcing bar corrosion rate determination. It combines state of the art embedded microprocessor systems and computerized flash technology, with the world's leading research in reinforcing bar corrosion rate analysis.

The Gecor 8 features:

  1. A method for rapidly mapping a structure's corrosion rate. An advanced modulation confinement technique for precise corrosion rate analysis.
  2. A new corrosion rate analysis technique for use in wet or submerged structures.
  3. New methodology for measurement of cathodic protection efficiency and more.


The rapid mapping technique of the Gecor 8 allows the engineer to quickly classify areas of the structure, while the unit's built-in programming can graphically analyze the data and produce contour maps of suspected areas. Our advanced modulation confinement technique accurately measures the true polarization resistance of the steel reinforcing bar.

Combined with the latest advances in interface systems and database storage technology, the Gecor 8 is an easy to use, reliable, automatic and intelligent corrosion rate analysis system. A system that can save an engineer time, money and effort in evaluating structures for subsequent rehabilitation.

 

Features & Benefits:

  • "giving the corrosion rate most closely matching the true value." (from the US Strategic Highway Research Program)
  • Rapid mapping capabilities for analysis of large structures.
  • Advanced method for more accurate corrosion rate determination.
  • New sensor design for analysis of wet or submerged structures.
  • New method for analysis of cathodic protection systems while the system is running.
  • Personal computer software for data analysis and report generation.
  • Graphical user friendly interface to facilitate measurements.
Please Note: Check an item and click on the text "Add To Cart" in order to select an item.  Simply checking a box will NOT add the item to your shopping cart.
Model Description Part No. Price Add To Cart

C-CS-8000

 Gecor 8 Basic System (Cu/Cuso4 Sensors for Corrosion Rate in Arial Structures)

28-C-CS-8000

Please email us or
call 1-800-635-9108 or 913-432-7080
for current pricing.

C-CS-8000A

 Gecor 8 Basic System (Ag/Agcl Sensors for Corrosion Rate in Arial Structures)

28-C-CS-8000A

Please email us or
call 1-800-635-9108 or 913-432-7080
for current pricing.

C-CS-8300

 Gecor 8 Complete System (Cu/Cuso4 Half-Cells includes Sensor A, B and C and Database Software

28-C-CS-8300

Please email us or
call 1-800-635-9108 or 913-432-7080
for current pricing.

C-CS-8300A

 Gecor 8 Complete System (Ag/Agcl Sensor A, B and C and Database Software)

28-C-CS-8300A

Please email us or
call 1-800-635-9108 or 913-432-7080
for current pricing.

Concrete >> Maturity & Temperature
James Instruments, Inc. : ASR Detect
Alkali silica reaction field test
 

Field Test to identify Alkali Silica Reaction (ASR) in concrete.

Two reagents are applied to the broken surface of a concrete core and the excess rinsed off. On contaminated concrete, the resultant stains reveal the presence of ASR. The stains also reveal the extent of the ASR in the concrete and indicate the stage of ASR progression. Yellow indicates that degradation has begun; pink warns that degradation is advancing.

Please Note: Check an item and click on the text "Add To Cart" in order to select an item.  Simply checking a box will NOT add the item to your shopping cart.
Model Description Part No. Price Add To Cart

I-AS-3000

 James Instruments, Inc. ASR-Detect

28-I-AS-3000

Please email us or
call 1-800-635-9108 or 913-432-7080
for current pricing.

Next   
1 - 3 of 22

top